Ettlingen, April 2005

In a production plant, 72 kg/h of NH3 containing portions of a highly inflammable constituent must be drawn off and cleaned to comply with the values required by TA-Luft. The highly inflammable constituent is contained in the gas in the form of drops and is not electrically conductive.

This application is particularly characterized by the high explosion protection requirements.

In accordance with ATEX, the gas chamber inside the scrubber belongs to category II 1G (zone 0), and the ambiance belongs to II 2G (zone 1).

GEA Jet Pumps have designed a two-stage process for this application based on the standard compact gas scrubber series.

The exhaust gas is drawn off by the jet scrubber and is cleaned to a large extent by chemical absorption in diluted sulphuric acid. The compliance with the specified limiting values is then ensured in the downstream counterflow column (2nd stage) by fine adsorption.

The entire plant has been designed for the operation in Ex-zone 0 and has been certified and homologated in a separate official acceptance procedure by the EXAM in Bochum, Germany.

The jet scrubber tube and the motive nozzle are made of material PP-EL. The gas scrubber is made of PP, is installed on a base frame made of galvanized steel and is equipped with a circulation pump and the necessary measuring and control equipment for pH value, level, density and temperature.